Troubleshooting for Antminer: Controller & Fan

4 Comments 2354 Views2


Troubleshooting for Antminer controller fan IMG 00

This is truouleshooting for Antminer controller & fan problems. Besides the suggestions in Tutorial: General Mining Guide & TroubleShoot for Antminer Models, here are some more troubleshooting ways.

 

Configuration page unaccessible

Possible causes and solutions:

 

IP address missing

Possible causes and solutions:

 

Fan undetected

Possible causes and solutions:

  • The fan is not properly connected -> Reconnect the fan.
  • Fan port on the control board damaged -> Request for warranty repair.
  • Fan damaged -> Change the fan or request for warranty repair.

 

Hash boards undetected

Possible causes and solutions:

  • Cable connection issue -> Power off the miner and reconnect the cable or change the cable.
  • Port damaged -> Request warranty repair.
  • Control board problem -> Request warranty repair.

 

Hash speed undetected

Possible causes and solutions:

  • Pool issue -> Change to another pool.
  • Fan issue -> Change the fan.
  • Hash board damage -> Request for warranty repair.
  • Control board issue -> Request for warranty repair.
  • Network problem -> Check the network.

 

Indicator lights for Internet port not working

Possible causes and solutions:

  • Ethernet cord issue -> Plug the Ethernet cord properly
  • Control board issue -> Request for warranty repair
  • Switch issue -> Check the switch

 

Spin speed of fans is too low (the speed difference of the 2 fans should be below 3000)

Troubleshooting for Antminer controller and fan IMG 01

Possible causes and solutions:

  • Change the fan, if it doesn’t help, request for warranty repair.

 

Kernel log page shows fan issue

Go to Kernel log page, search “error”, if it shows: Fatal Error: some Fan lost or Fan speed low.

Possible causes and solutions:

  • Fan not connected properly -> Reconnect the fan.
  • Fan port on the control board damaged -> Request warranty repair.
  • Fan damaged -> Request warranty repair.

 

Third fan detected

Possible causes and solutions:

  • Replace the two fans, see if the problem goes away.
  • If both fans changed yet the problem persists, request for warranty repair.

 

Fan spin speed exceeds 7000

Troubleshooting for Antminer controller and fan IMG 02

Possible causes and solutions:

  • Replace the two fans, see if the problem goes away.
  • If both fans changed yet the problem persists, request for warranty repair.

 